The lighting switch shall be located so as to be readily accessible from the pit access door. Other terms defined in NEC Article 620 are Control System, Motion Controller, Motor Controller, Operation Controller, Operating Device and Signal Device. Elevator travel is far safer than an automobile trip, and the chance of experiencing disaster is on the order of being struck by lightning in ones own backyard. The feeder OCPD needs to remain closed so the remaining elevators have power and continue to function. If elevators are supplied by the emergency, legally required standby or critical operation power systems, then selective coordination is required per the 2017 NEC in 700.32, 701.27 or 708.54. It provides that where more than one driving-machine disconnecting means is supplied by a single feeder, the overcurrent protective devices in each disconnecting means are to be selectively coordinated with any other supply side overcurrent protective devices. NEC Article 0: Elevator art by David Herres Continued. All of these options and special wiring can be challenging depending upon the location of the shunt trip circuit breaker as well as who has responsibility for providing these additional options. Eazylift Albany LLC, 836 Troy Schenectady Rd, Latham, NY, Elevators of the sprinkler heads. Sign up for our free e-newsletter. Electricity is often one of the initial services to fail during a storm. 3. Requirements for commercial garages per the National Electrical Code. ) > word/_rels/document.xml.rels ( N0HC;qRN/W$#{1EM]ZY|vj5h),-g!`./V/KKFY4D#la&V#=$Q7|l/d#hS 7+IDZ!J 6KucD^s`+>=(3E The disconnecting means is to be an externally enclosed, operable, fused motor circuit switch or circuit breaker capable of being locked in the open position. Hammurabi, sixth king of Babylon and creator of the Babylonian Empire, decreed: If a builder builds a house for someone and does not construct it properly, and the house which he built falls in and kills its owner, then that builder shall be put to death. The traveling cable or raceway is also permitted to include shielded conductors and/or one or more coaxial cables. They are differentiated from other similar structures by the fact that they are not attached to the outside perimeter or surface of the walls, ceiling or floor of the hoistway. Part III, Wiring, looks at the types of wiring that may be installed in hoistways, cars, machine rooms and related spaces. You must run a separate insulated grounding conductor with the feeder conductors from the electrical source to the elevator controller. A traction elevator's equipment room is typically located at the top of the building, directly over or adjacent to the shaft. This is typically accomplished via a shunt trip device. Hydraulic elevators are typically more cost effective and used for buildings up to 5-6 stories. In many cases, the overcurrent protective devices that are suitable for this level of protection are current-limiting fuses rather than a traditional circuit breaker. We resume with a look at wiring methods, overcurrent protection, grounding and other NEC provisions as they relate to these installations. In such cases, it's economically justifiable to specify a traction type elevator. See Section 3 of the. This is important as the tradition of using only time-current curves for the analysis of overcurrent device operation is usually not sufficient since the time-current curves traditionally stop at 0.01 second (not time zero). Traction elevators raise and lower the elevator cab with cables, a pulley system, and counter weights powered by a motor at the main drive wheel. When you're designing an electrical system for a building, don't let elevator requirements bring you down. Sumps and sump pumps in pits, where provided, shall be covered. By subscribing, you agree to our User Agreement and Privacy Policy & Cookie Statement. With heavy use on a hot day, the oil can overheat, causing elevator shutdown. It is further stressed that no provision is to be made to open or close the disconnecting means from any other part of the premises. Corporate Office Heating and air-conditioning equipment located on the car must not be in excess of 600 V. All live parts of electrical apparatuses are to be enclosed to protect workers and the public against accidental contact. hb``` ea``j~p2nfH
'xXg00,/(_ Iq8PDdg-~ s$!XI;Fn0vu
`h`R 1y
0B.":9.@, e`xI;=7O3fvbb8:SC;%O*20] Elevator Pit FC Requirements CE017 - 1 - AppendicesABC - Code Motor feeder short circuit and ground-fault protection must be as required in Article 430, Part V for all motors. Sign up for our free e-newsletter. wide or the width of the equipment, whichever is greater. The light switch shall be located so to be accessible from pit access door. Section 620.62, Selective Coordination, is central to multi-elevator installations and must be closely observed. Similarly, the integrity of the traveling cable is emphasized. You need to Subscribe to continuing reading. The idea is quite simple. Please include what you were doing when this page came up and the Cloudflare Ray ID found at the bottom of this page. Metal grating shall be installed over the hole that sits flush with the pit floor. It begins by considering metal and nonmetallic wireways. or larger, not exceeding 6 ft. in length, are permitted between control panels and machine motors, machine brakes, motor-generator sets, disconnecting means and pumping motors and valves. Your elevator supplier will take care of all the wiring and related code requirements for the elevator cab and the various controls. Dec. 21, 2010. NEC Article 620 Part V, Traveling Cables, is driven by two major issues. It need not be exactly centered on the equipment, and working spaces of adjacent pieces of equipment may overlap. In all cases, the working space must permit at least a 90 opening of equipment doors or hinged panels. Part VII, Overcurrent Protection, divides this topic into four categories for elevators and similar equipment, depending upon the nature of the specific equipment: For operating devices and control and signaling circuits, protection against overcurrent is in accordance with the requirements of Sections 725.43 and 725.45. The demand factor ranges from 1.00 for one elevator on a single feeder to 0.72 for 10 or more elevators on a single feeder. ,l7CLHmcX9*F -{Q|^"XL`b1y]$,y *R/2Rn{\xG
L*vMP.uKW,)68]Y}+ FYS1B=Q0S>Hc Machine room-less elevator installations incorporate the elevator controller and often the primary disconnecting means in a convenient package that is located within the elevator shaft. The electrical conductors and equipment for non-mine elevators that extend below grade are under NEC jurisdiction. Another important electrical system design consideration for supplying power to multiple elevators is NEC 620.62. The article stands apart from the rest of the code in the sense it exempts these categories of circuits from the general requirements for wiring in most occupancies, found in Chapter 3. Limit switches placed throughout the height of the shaft communicate with the controller and stop the cab at each landing. David Herres holds a New Hampshire Master Electricians license and has worked as an electrician in the northern part of that state for many years. 6 Stop Switch in Pits There shall be installed in the pit of each elevator an ASME A17.1 CODE enclosed stop switch or switches meeting the requirements The following material is reprinted with permission from the American of 2.26.2.7 and 2.2.6.1 through 2.2.6.3. PDF Compliance with the 2017 NEC for Elevator Controllers Additional requirements concern escape routes. 2.2.6.1 This switch shall be so located as to be acces-sible from the pit access door. Receptacle for pumps located in the pit shall be a single non-GFCI and shall be located 6 inches above the lowest landing. If your specifications require a vent at the top of the shaft for venting smoke, you must provide a key switch with a pilot light to control that vent. Such cable groups are to be supported at intervals not over 3 ft. and located so as to be protected from physical damage. Pits shall be maintained in a clean and dry condition. z!0: - [Content_Types].xml ( n0EUb*>-RxV=QUAl"93dFk%Y?l}MGDV Elevators with driving machines located on the car or counterweight, or in the hoistway are permitted outside the specified spaces. Both electric and nonelectric elevators are to comply with Article 250, the code article that covers grounding and bonding in general. 2.2.2.6 . The proposals resulted in adding new requirements in the 2017 NEC for: Marking the elevator controller short-circuit current rating (SCCR) by the elevator control-ler manufacturer. Traction elevators are typically faster and more energy efficient than hydraulic elevators, and are often used for high-rise buildings. A raceway that comes loose on the inside of a hoistway could catch on a moving car, causing immense damage and hazard to users. Every building is different. or larger is permitted to be installed in lengths in excess of 6 ft. Where motor-generators, machine motors or pumping-unit motors and valves are located adjacent to or underneath control equipment and provided with extra-length terminal leads not exceeding 6 ft. in length, such leads are permitted to be extended to connect directly to controller terminal studs without regard to carrying-capacity requirements. In hoistways not longer than 6 ft., these additional wiring methods are permitted: A sump or oil-recovery pump located in the pit is permitted to be cord connected. Guarding: Where possible, install temporary guarding to protect from inadvertent contact. The action you just performed triggered the security solution. For instance, one method to reduce the available fault current is to add an isolation transformer ahead of the elevator controller. Therefore, there will be two signals to the elevator control panel related to smoke detectors: one from the designated floor smoke detector and another combined signal from the smoke detectors at the other lobby landings and in the equipment room. The fan should be on a dedicated circuit. This website is using a security service to protect itself from online attacks. Where voltages exceed 600, a sign reading DANGER HIGH VOLTAGE is required. Hydraulic reservoir characteristic of a hydraulic-piston-operated elevator. Motors for traction elevators were traditionally DC or synchronous, but new installations use AC motors and VFDs for speed control. You are a subscriber that needs to Sign In. Additionally, duty on elevator and dumbwaiter motors is rated as intermittent, whereas duty on escalator and moving-walk motors is considered continuous. The basic idea is that there must be a separate, dedicated circuit for car lights, receptacles and ventilation on each car. Since 1953, Elevator World, Inc. has been the premier publisher for the global vertical transportation industry. The demand factors are given in Table 620.14, which allows significant reductions as the number of motors is increased. The conductors must be in their original sheaths or grouped together and taped or corded. Other requirements: Spa's and Hot Tubs 1996 NEC 15-20 Amp 120 volt Receptacle Requirements for Dwelling units: All outdoor Marking the available short-circuit (fault) current on the controller by the equipment installer. In fact, an entire elevator system for a project is most often designed and specified by the architect who has little understanding of the electrical distribution system. Design practices that are acceptable in some jurisdictions may not be in others. The code notes that elevator rails or other hoistway equipment are not to be used as the grounding conductor for lightning-protection systems. Performance & security by Cloudflare. PDF NEC Article 0: Elevator art If the entire feeder/branch circuit assembly were to be protected in the conventional manner, the motor would cut out long before reaching operating speed. Part VIII, Machine Rooms, Control Rooms, Machinery Spaces, and Control Spaces, states elevator and similar-installation driving machines, motor-generator sets, motor controllers and disconnecting means are to be installed in a room or space set aside for that purpose. Therefore, elevator equipment rooms must maintain a temperature between 50F and 90F. employees shall not perform any work on equipment where there is a potential to come in contact with energized mechanical or electrical hazards until all sources of energy have been de-energized, grounded or guarded.. Supports for cables or raceways in a hoistway or in an escalator or moving-walk wellway or platform lift and stairway chairlift runway must be securely fastened to the guide rail, escalator or moving-walk truss, or to the hoistway, wellway or runway construction. +1-251-479-4514 | [emailprotected], Trkiye Office To safeguard the passengers and electrical equipment, ASME A17.12.8.2.3.2 requires the power source to the elevator control panel to shut down prior to the discharge of water from a sprinkler head. +90 (216) 348 4876, India Office You need to Subscribe to continuing reading. A second door is required if the equipment is rated over 1200 amps and over 6 ft. wide. 1. Suspending the cables from the supports by a means that automatically tightens around the cable when tension is increased for unsupported lengths up to 200 ft. An NEC Informational Note defines unsupported lengths. This may be countered by providing good machine-room ventilation. Regardless of the number of elevators, only one smoke detector is required at each floor lobby, but it must be located within 21 ft of every elevator door. NEC Article 620 covers elevators, dumbwaiters, escalators, moving walks, platform lifts and stairway chairlifts. In the event of a breakdown, that phone must automatically call a location staffed 24 hours a day. Accordingly, for this application, the minimum size is reduced to 20 AWG for lighting circuits. Motor controllers are permitted outside the spaces specified above. These are: remote machine room and control room (for elevator and dumbwaiter), and remote machinery space and control space (for elevator and dumbwaiter). The cover shall be secured and level with the pit floor. You'll be responsible for specifying the items related to the fire alarm and some controls, as well as supplying lighting and power to the equipment room and elevator pit. above the seal plate, adjacent to the ladder. Below is a summary of these new 2017 NEC sections: In order to comply with these requirements a chain of events must occur. After reading this article, you should have learned: Which locations require sepa-rate, dedicated branch circuits Which branch circuits are not to be provided with ground fault circuit interrupter (GFCI) pro-tection Which locations must have one or more duplex receptacles Where overcurrent protection for hoistway, pit and machine-room lighting must be located How unsupported lengths of traveling cables are measured. Additional branch circuits are to supply other utilization equipment not covered above. The locking capability is important so during maintenance, the equipment will not be inadvertently energized. from components that are not otherwise guarded. Examples of PPE that may be appropriate are non-conductive eye protection, clean leather or fire-resistant gloves, and natural-fiber or fire-resistant-rated long-sleeved shirts and pants, or fire-resistant-rated long-sleeved coveralls. The pump sends hydraulic fluid from the reservoir to the cylinder, buried deep below the elevator shaft. Because of this, there is often a communications gap between the electrical system designer, whose design typically stops at the required elevator disconnecting means, and the architect who designs the elevator system.